- Spare Parts
In-situ Dilution Probe -
Coarse Filter Screen -- P/N E-IS-RPLC-005:
Material
Monel® | OD
19MM
Description: For use with the filter cap assembly of
the in-situ diluting sample probe. This screen has 19mm OD
and is used with the newer style cap assembly.
Coarse Filter Screen -- P/N E-IS-RPLC-003:
Material
Monel® | OD
21MM
Description: For use with the filter cap assembly of
the in-situ diluting sample probe. This screen has 21mm OD
and is used with the older style cap assembly.
Circlips -- P/N E-IS-RPLC-002:
Material
Stainless Steel 316
Description: For use with the older style filter cap
assembly on the in-situ diluting sample probes, to retain
the coarse filter screen in the front of filter cap.
Filter Cap Assembly -- P/N E-IS-RPLC-014:
Material
Inconel® | Includes
Front Cap, Coarse Screen & Filter Union
Description: For use with heated in-situ diluting sample
probes. Note: This is the newer style (3-piece) filter cap
assembly, has groove on front cap for Kalrez® O-ring if
sampler is heated.
Filter Cap Assembly -- P/N E-IS-RPLC-015:
Material
Stainless Steel 316/316L | Includes
Circlip, Coarse Screen & Filter Cap
Description: For use with in-situ diluting sample probes.
Note: This is the older style filter cap assembly, does not
have O-ring groove, coarse screen is secured to front using
a circlip.
O-ring -- P/N GS-K118:
Material
Kalrez® | Max. Temp.
575°F (300°C)
Description: For use with the in-situ dilution probes.
For the Kalrez® O-ring used in the Out-of-Stack diluting
sample probe, use P/N: GS-K116.
Front Mantle -- P/N E-IS-RPLC-007:
Material
Inconel®
Description: For use with standard Stainless or Inconel®
in-situ diluting sample probes, or high temperature (Inconel®)
in-situ diluting sampler. This part is located between aspirator
section and filter cap assembly, as housing for the critical
orifice.
In-line Filter Assembly -- P/N 5000.167:
Material
Stainless Steel | Micron Size
60µ
Description: For use with Dilution Air line of the
in-situ (and out-of-stack) diluting sample probes. Complete
with 60µ filter cartridge. End connections are both
for 1/4" OD tubes.
Replacement Filter Cartridge -- 5000.183:
Material
Stainless Steel | Micron Size
60µ
Description: Replacement cartridge for in-line filter,
used with Dilution Air line of the in-situ (and out-of-stack)
diluting sample probes.
Graphite Ferrules -- P/N GS-GFER.25:
ID
1/4" | Qty.
10pc. Pak
Description: For use with the standard glass critical
orifice. Provides leak-tight seal between critical orifice
and front of in-situ (and standard out-of-stack) diluting
sample probes.
Pure Quartz Wool -- P/N FM-QWOOL-2M-XXG:
Micron Size
2µ/Ultra-fine | Qty.
10g/50g/100g Bags
Description: For fine-filter replacement in the glass
critical orifice, or in Monel critical orifice pre-filter.
Note: approximately .7 to 1g of quartz wool is used to for
refilling the above noted parts. Replace "XX" in
Part Number to specify quantity in grams (e.g., FM-QWOOL-2M-10G
= 10 gram bag of quartz wool).
Nickel Anti-Seize Compound -- P/N GRS-NAS-01C:
Temperature Rating
Up to 2400°F (1315°C) |
Qty.
1/2 OZ.
Description: For use as lubricant that protects threaded
parts from seizing and galling. Recommended for the threads
of the stainless steel and Inconel® Filter Cap Assemblies,
Front Mantles, In-situ diluting sample probe tip, etc.
Looking for Critical Orifices?
Click Here.
For
Replacement parts specific to the EPM Out-of-Stack
Diluting Sampler,
Click Here.
Can't find the part your looking for?
Contact Us.
Next
|